Gold Member Since 2016
Audited Supplier
TRYTE TECHNOLOGY (HUNAN) DEVELOPMENT CO., LTD.

Differential Scanning Calorimeter, Auto Differential Scanning Calorimeter, Full Auto Differential Scanning Calorimeter manufacturer / supplier in China, offering Differential Scanning Calorimeter-Auto Differential Scanning Calorimeter Test, Gas Chromatography-Gas Chromatography Equipment, Automatic Proximate Analyzer (TGA) -Coal Testing Equipment and so on.

(/ )

Supplier Homepage Product Test Machine Differential Scanning Calorimeter-Auto Differential Scanning Calorimeter Test

Differential Scanning Calorimeter-Auto Differential Scanning Calorimeter Test

FOB Price: US $1-13,500 / Piece
Min. Order: 1 Piece
Min. Order FOB Price
1 Piece US $1-13,500/ Piece
Get Latest Price
Port: Shenzhen, China
Production Capacity: 15000PCS/Year
Payment Terms: L/C, T/T, Western Union, Paypal

Request a custom order and have something just for you!

Send Customized Request
Basic Info
  • Model NO.: TRC-1500B
  • Maxcapacity: Program Control
  • Load Way: No
  • Display: Touch Screen Type
  • Weight: 15kg
  • Oil Cylinder Position: No
  • Trademark: TRYTE
  • Specification: Stainless Steel
  • Type: Material Testing Machine
  • Accuracy Grade: 0.1
  • Loading Method: Static Load
  • Control: Computer Control
  • Power Source: AC220V
  • Quality: Same as OEM
  • Transport Package: Paper/Wood Box
  • Origin: China/Hongkong
Product Description

Differential Scanning Calorimeter-Auto Differential Scanning Calorimeter Test
phase transition/molten glass transition temperature, thermal stability of enthalpy/product/oxidation

induction period.

Technical features

1,Industrial grade widescreen touch structure, display rich information, including the setting temperature,

sample temperature, oxygen flow rate, the nitrogen flow rate, differential thermal signal, status of various

switches, flow zero.

2,USB communication interface, strong, reliable signal is not interrupted, support for self recovery connection.

3,The furnace body is compact, and can be adjusted at any temperature.

4,Improve the installation process, the use of mechanical fixed way, completely avoid the furnace body of the

colloidal particles of the heat signal pollution.

5,Double temperature probe to ensure the high repeatability of sample temperature measurement. A temperature

probe is installed on the furnace wall for PID control of the whole furnace temperature, but due to the temperature

of the thermal inertia, conduction to the temperature of the sample is not the same, therefore, the use of single

temperature probe temperature and temperature control, no matter whether the temperature signal, the error is

relatively large, the instrument is used to measure the true temperature of the sample, and the temperature of the

sample is controlled by temperature.

6,Digital gas mass flowmeter gas flow automatic switching two road, switching speed, stable time is short.

7,With standard sample, convenient customer constant temperature correction coefficient.

8,The software adaptive resolution computer screen, the software automatically according to the computer display

screen size to adjust the curve. Support for notebook, desktop, support the WIN2000, XP, VISTA, Windows 7

operating system.

9,Support user programming procedures, to achieve automatic measurement step. Software provides dozens of

instructions, the user can according to your own measurement steps and combined each instruction, and save. Complex

operation is simplified into a key type operation.

Technical parameters

Temperature range

At room temperature- 1500 degrees

Working power supply

AC220V 50 hz or custom

The temperature accuracy

0.1ºC (standard metal sample)

Atmosphere control of gas

Nitrogen, oxygen (automaticswitching apparatus)

 

Heating rate

0.1-80ºC/min

Gas flow

0-200ml/min

The temperature control mode

Heating, constant temperature (fully automatic control)

 

Gas pressure

0.2mpa

DSC range

0-500±mw

Accuracy of gas flow

0.2ml/min

DSC noise

0.01μw

Optional crucible

 

Aluminum alloy crucible diameter 6.6 * 3, ceramic crucible (alumina crucible) phi 5 * 4 mm

 

DSC resolution

0.01μw

Parameters of the standard

Equipped with standard sample (indium, tin, zinc) users can correct temperature and heat enthalpy

 

DSC accuracy

0.01μw

Data interface

Standard USB interface

 

DSC sensitivity

0.01μw

 

 

Output way

Computer and printer

 

Display mode

24 bit color, 7 inch LED touch screen display

 

 

Examples of application

Professional analysis of organic and inorganic materials in the process of temperature control the heating

effect of the nature of the physical or chemical changes occur, and the corresponding temperature for test

analysis, the enthalpy change, the glass transition temperature, melting point determination of the parameters

such as phase change temperature, kinetics. Instrument conforms to the national standard GB/T 199466.2 2004

/ ISO 2004-99: in the part 2: determination of the glass transition temperature, GB/T 19466.3 2004 / ISO 11357

 - and 99 part 3: determination of fusing and crystallization temperature and heat enthalpy.

Differential Scanning Calorimeter-Auto Differential Scanning Calorimeter Test


Differential Scanning Calorimeter-Auto Differential Scanning Calorimeter Test



Differential Scanning Calorimeter-Auto Differential Scanning Calorimeter Test

Send your message to this supplier
Avatar
Ms. Lucy
*From:
To: Ms. Lucy
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now