• Auto Solid Phase Extraction System
  • Auto Solid Phase Extraction System
  • Auto Solid Phase Extraction System

Auto Solid Phase Extraction System

Customized: Customized
Structure: Desktop
Material: Stainless Steel
Certification: CE, RoHS
Application: School, Hospital, Lab
Type: Container
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
02HT/04HT/PLUS/06HT
Quality
Excellent
Power
110/220V AC, 50/60Hz
Weight
26kg
Analyzer
Analyze- LC-Ms-Ms
Transport Package
Paper/Wood Box
Specification
AC 100-240V, 50Hz/60Hz
Trademark
TRYTE
Origin
China/Hongkong
Production Capacity
1500PCS/Year

Product Description

Auto Solid Phase Extraction System

Auto Solid Phase Extraction System

02HT Specification (2 channels)
1.Application: for food, beverage, water, blood, urine and soil sample trace organics extraction under liquid, solid or semi-solid sample phases, especially the analysis of trace organic compounds in food. It is the best sample preparation device for GC, LC and GC/MS analysis. 
2.It fully automates the entire process of solid-phase extraction (condition, Sample loading, rinsing, drying and elution).
3.Two high-precision syringe pumps to achieve two channels simultaneously for condition, sample loading and the elution.
4.Flow speed range:0.1mL/min-100mL/min.
5.Automatically process 20 samples continuously, can be expanded to maximum 12 channels which continuously and automatically handle 120 samples without human intervention.
6.Unique column plunger seal technology. With the plunger positioned closely to the surface of SPE column packing. The control of liquid flow rate become accurate as the flow rate of the syringe pump will be just the same as the actual liquid flow through the SPE column, avoiding solvent mixture, ensuring Recovery of the sample and Parallelism.
7.Utilize 12 ports valves to select solvents, fast and no cross contamination 
8.Applicable extraction column: 1ml, 3ml, 6ml and 12ml standard column.
9.Accommodate 8 kinds of organic solvents for condition, rinse and elution. All flow paths can be cleaned automatically.
10.Column with string function
11.With automatic nitrogen purge function, the instrument can dries SPE column on line. In addition, separate nitrogen with three ports valve switch shall be integrated to ensure a constant flow rate and continuity, good drying effect.
12.Optional sample tubes for variety of specifications: 20mL-80mL etc. Optional collect tubes for variety of specifications15mL-60mL etc.
13. Unique filter net that compatible with sample tube to clean sample before loading process.   
14.Pressure (N2) Input: maximum 100 psi; Output: 0 - 20 psi.
15.Waste separation: three waste lines that can collect the aqueous waste, organic waste and chlorine related other organic waste separately.
16.Materials contact with solvent: stainless steel, gold/platinum coating, Teflon or PEEK.
17.Software: Windows-based operating system control software.
18. Control system: WIFI connection, enable users to remotely control and monitor the instrument.
19. Being free from connection of PC and designed in compact size, the instrument can be placed in the fume hood.




Plus Specification (6 channels)
1. Application: for food, beverage, water, blood, urine and soil sample trace organics extraction under liquid, solid or semi-solid sample phases, especially the analysis of trace organic compounds in food. It is the best sample preparation device for GC, LC and GC/MS analysis. 
2. It fully automates the entire process of solid-phase extraction (condition, Sample loading, rinsing, drying and elution).
3.Six high-precision syringe pumps to achieve two channels simultaneously for condition, sample loading and the elution.
4.Flow speed range:0.1mL/min-100mL/min.
5.Automatically process 60 samples continuously, can be expanded to maximum 32 channels which continuously and automatically handle 320 samples without human intervention.
6.Unique column plunger seal technology. With the plunger positioned closely to the surface of SPE column packing. The control of liquid flow rate become accurate as the flow rate of the syringe pump will be just the same as the actual liquid flow through the SPE column, avoiding solvent mixture, ensuring Recovery of the sample and Parallelism.
7.Utilize 12 ports valves to select solvents, fast and no cross contamination 
8.Applicable extraction column: 1ml, 3ml, 6ml and 12ml standard column.
9.Accommodate 8 kinds of organic solvents for condition, rinse and elution. All flow paths can be cleaned automatically.
10.Column with string function
11.With automatic nitrogen purge function, the instrument can dries SPE column on line. In addition, separate nitrogen with three ports valve switch shall be integrated to ensure a constant flow rate and continuity, good drying effect.
12.Optional sample tubes for variety of specifications: 20mL-80mL etc. Optional collect tubes for variety of specifications15mL-60mL etc.
13. Unique filter net that compatible with sample tube to clean sample before loading process.   
14.Pressure (N2) Input: maximum 100 psi; Output: 0 - 20 psi.
15.Waste separation: three waste lines that can collect the aqueous waste, organic waste and chlorine related other organic waste separately.
16.Materials contact with solvent: stainless steel, gold/platinum coating, Teflon or PEEK.
17.Software: Windows-based operating system control software.
18. Control system: WIFI connection, enable users to remotely control and monitor the instrument.
19. Being free from connection of PC and designed in compact size, the instrument can be placed in the fume hood.


Packing:

Auto Solid Phase Extraction System


Company Information:

      As a diversified manufacturer of high-tech products, it was founded in 1999, and devoted to the products, sales and technical service for various industries and fields like Energy analysis instrument, Oil, coal, steel, and geology; medical analysis and application instruments, biochemistry analyzer, elisa reader, blood analyzer,and urine; as well as laboratory application instruments,autoclave/sterilizer,freeze dryer, incubator,drying oven,balance,ICP,DRS,HPLC,gas chromatography,and spectrophotometer,meanwhile,TRYTE Technologies integrated and purchased some companies of PCB board, highway instruments at home and abroad. Our company has become the "one stop" instrument procurement service provider worthy of the name.
      TRYTE technologies (TRYTE) mainly sell products by selling direct to customer, but also through distributors, resellers and manufacturer representatives, telephone sales and e-commerce sales, customers cover all over 80% of the world's countries and regions.TRYTE have solutions with rules adaptability according to the specific requirements of the design, from the instrument to some laboratories or departments.Whichever kind of solution you choose, you can fully trust it, because it is proved from 100, 00 successful results, leading development process, and decades of actual certification experience.

Auto Solid Phase Extraction System


Why choose us?

1. We supply high quality products with reasonable price.
2. We are the professional manufacturer;
3. Advanced production machine;
4. Strict quality control system;
5. Ten people research&develop team;
6. We have professional sales team;

Auto Solid Phase Extraction System
 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
30
Year of Establishment
2008-07-03