• Lab Ftir Spectrometer-Ftir Instrument
  • Lab Ftir Spectrometer-Ftir Instrument
  • Lab Ftir Spectrometer-Ftir Instrument
  • Lab Ftir Spectrometer-Ftir Instrument

Lab Ftir Spectrometer-Ftir Instrument

Application: Laboratory Apparatus
Warranty: > 1Year
Detection Method: Spectrophotometer
Advantage: High Resolution
Principle: Ftir
Wavelengths: 7800 to 350 Cm-1
Customization:
Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company

Basic Info.

Model NO.
FTIR-W30
Dispersive Element
Prism Spectrometer
Light Number
Polychromator
Certification
RoHS, ISO9001, CE, SGS
Customized
Customized
Transport Package
Paper/Wood Box
Specification
AC 100-240V, 50Hz/60Hz
Trademark
TRYTE
Origin
China/Hongkong
Production Capacity
110PCS/Year

Product Description

FTIR Spectrometer( FTIR-W30)

Lab Ftir Spectrometer-Ftir Instrument


Based on more than thirty years experience in FTIR R&D and manufacturing, TRYTE has launched a new type FTIR Spectrometer FTIR-W30 with fully independent intellectual property rights.  Adhering to consistent excellent quality and superior performance, the new model obtains the best balance between intelligence and convenient operation, advance performance and low operation and maintenance cost.  It is a good choice for basic science research analysis, production quality control,testing and detection in various fields.
  1. High sensitivity and stability
  2. Intelligent real-time monitoring of instrument status
  3. Multiple communication options
  4. Flexible and convenient testing
  5. Powerful software workstation
Innovations
Real-time diagnosis of instrument status:  real-time monitoring of instrument working status, performance and communication status.status,ensuring the instrument always to work in a stable state.
 
Optional temperature stabilized, high sensitivity DLATGS detector module,  providing stable detector response,thus ensuring high sensitivity, good reproducibility and stability of IR spectral analysis.

"Internet+ detection" instrument design with multiple communication options: Ethernet interface as standard supply for data transfer, WIFI wireless communication as an option, adapting to "Internet+ detection" instrument development trend, setting up a basic platform for interconnected tests, remote operation and maintenance, and data cloud computing.

Lab Ftir Spectrometer-Ftir Instrument
Lab Ftir Spectrometer-Ftir Instrument
Brand-new powerful MainFTOS Suite software workstation
Lab Ftir Spectrometer-Ftir Instrument

Features
  1. High sensitivity optical system: cube-corner Michelson interferometer combined with patented fixing mirror alignment technology(Utility model ZL 2013 2 0099730.2:fixing mirror alignment assembly),to ensure long term stability, without the need of dynamic alignment which needs extra complicated electronic circuits.  Reflecting mirrors are coated with gold to provide the maximum light throughput and ensure the detection sensitivity.
  2. High stability modular partition design: compact structure modular design with layout on cast aluminum base and overall balance of mechanical robustness and partition heat dissipation, offering higher ability of deformation resistance and less sensitive to vibrations and thermal variations, greatly improves the mechanical stability and long term working stability of the instrument.
  3. Intelligent multi-sealed moisture-proof design: multiple sealed interferometer, large-capacity desiccant cartridge with visible window and easy replacement structure, real-time monitoring of temperature and humidity inside the interferometer, getting rid of influences of high temperature, high humidity and chemical corrosions to the optical system in many ways.
  4. Innovated integration electronic system:  high sensitivity integrated DLATGS detector pre-amplifier technology, dynamic gain amplification technology, high precision 24-bit A/D conversion technology, real-time control and data processing technology, digital filter and network communication technology, ensuring high quality real-time data collection and high-speed transmission.
  5. Good anti-electromagnetic interference capability: The electronic system is designed to meet CE certification and electromagnetic compatibility requirements, minimizing electromagnetic radiation in design and technology,in line with green instrument designing concept.
  6. High intensity IR source assembly: High intensity, long lifetime IR source module, with the highest energy distributed in fingerprint region, adopts a reflex sphere design to obtain even and stable IR radiation. External isolated IR source module and large space heat dissipation chamber design provide higher thermal stability and stable optical interference.
  7. The sampling compartment, reserving accessory mounting holes on the base plate, is wide enough for various accessories such as Defused/Specular Reflection, ATR, Liquid cell, Gas cell, and IR microscope etc.

Specifications:
Interferometer Cube-corner Michelson interferometer  
Beam splitter Multilayer Ge coated KBr  
Detector Room temperature DLATGS module (standard) Temperature stabilized, high sensitivity DLATGS module (optional)
IR Source High intensity, long lifetime, air-cooled IR source  
Wavenumber Range 7800cm-1~350cm-1  
Resolution 0.85 cm-1  
Signal to noise ratio Better than 20,000:1 (RMS value, at 2100cm-1 ~ 2000cm-1 or 2100cm-1 ~ 2200cm-1, resolution: 4cm-1, detector: DLATGS, 1 minute data collection)  
Wavenumber Accuracy ±0.01 cm-1  
Scanning Speed Microprocessor control, different scanning speed selectable.  
Software Main FTOS Suite software workstation, compatible to all version Windows OS Various specialized functional software modules (optional)
Communication Ethernet interface (standard) WIFI wireless communication (optional)
Data Output Standard data format, report generation and output  
Status Diagnosis Power on self check, real-time temperature and humidity monitoring and reminders  
Certification   FDA 21 CFR Part11 compliance,IQ/OQ/PQ(Optional)
Environment Conditions Temperature: 10ºC~30ºC,
humidity: less than 70%
 
Power Supply AC220V±22V,50Hz±1Hz AC110V(optional)
Dimensions & Weight 520 x 435 x 255mm, 24kg  
Accessories Transmission sample holder (Standard) Optional accessories such as gas cell, liquid cell, Defused/Specular Reflection, single/multi reflection ATR, etc.

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now

You Might Also Like

Gold Member Since 2016

Suppliers with verified business licenses

Manufacturer/Factory & Trading Company
Number of Employees
30
Year of Establishment
2008-07-03