Engler Viscometer-Engler Viscometer (Double Units) -Oil Testing Instrument

Product Details
Customization: Available
Quality: Same as OEM
Color: Mix Colour
Manufacturer/Factory & Trading Company
Gold Member Since 2016

Suppliers with verified business licenses

Audited Supplier

Audited by an independent third-party inspection agency

Number of Employees
30
Year of Establishment
2008-07-03
Find Similar Products

Basic Info.

Model NO.
TR-TNE-1B
Type
Oil&Petroleum
Application
Base Oil, Derivatives, Oil&Petroleum, Oil Product
Transport Package
Paper/Wood Box
Specification
AC 100-240V, 50Hz/60Hz
Trademark
TRYTE
Origin
China/Hongkong
Production Capacity
5000PCS/Years

Product Description

Engler Viscometer-Engler Viscometer (Double Units) -Oil Testing Instrument
Engler Viscometer-Engler Viscometer (Double Units) -Oil Testing Instrument
I.Description

 Engler Viscometer is designed and made as per the National Standard GB/T266 "Test Methods for Engler Viscosity of Petroleum Products" and the Industry Standard JTJ052Specification and Test Methods of Bitumen and Bituminous Mixture for Highway Engineering. It is used to determine the ratio obtained by dividing the time of flow, in s, of 200 ml of material using an Engler viscometer at a selected temperature by a factor representing the time of flow, in s, for an equal volume of water at 20 ºC. The ratio is the Engler viscosity of the sample. The instrument can make determination for 2 samples at the same time in the same temperature environment. It can also calculate the average value of these test results. It is the best instrument for Engler viscosity of petroleum products and bituminous materials determination.

II. Main technical specification and parameters
1. Power supply: AC 220 V±10%, 50 Hz;
2. Standard water value: 51±1 s;
3. Temperature measurement range: 0ºC~100 ºC;
4. Temperature controlling accuracy: ±0.1 ºC;
5. Engler viscometer thermometer: as per standard GB/T514;
6. Measuring flask specification: 100±0.2 ml (asphalt sample is 50±0.2 ml);
7. Inner container: stainless steel;
8. Time measurement range: the maximum is 999 s;
9. Timing mode: LED timer;
10. Heating power: 700 W;
11. Ambient temperature: -10ºC~+40 ºC;
12. Relative humidity: ≤85%;
13. Total power consumption: not more than 800 W;


 Measurement record

Standard water temperature 25±0.2 ºC Measured water value at first time  
Standard water value 11.4±0.2 s Measured water value at second time  
Real temperature ºC Average water value  
 
 
Full set and technical documents
1. Full set
No Name Unit Quantity
1 Main unit Set 1
2 Temperature sensor Piece 1
3 Receiving flask (100 ml) Piece 2
4 Engler thermometer 0~50 ºC, scale division is 0.1 ºC Piece 1
5 Engler thermometer 0~100 ºC, scale division is 1.0 ºC Piece 1
6 Wooden stopper of viscometer Piece 2
7 Fuse 10 A (Φ5×20) Piece 2
8 Stopping ring for thermometer (1#) Piece 2

Engler Viscometer-Engler Viscometer (Double Units) -Oil Testing Instrument
Packing:

Engler Viscometer-Engler Viscometer (Double Units) -Oil Testing Instrument


Company Information:

      As a diversified manufacturer of high-tech products, it was founded in 1999, and devoted to the products, sales and technical service for various industries and fields like Energy analysis instrument, Oil, coal, steel, and geology; medical analysis and application instruments, biochemistry analyzer, elisa reader, blood analyzer,and urine; as well as laboratory application instruments,autoclave/sterilizer,freeze dryer, incubator,drying oven,balance,ICP,DRS,HPLC,gas chromatography,and spectrophotometer,meanwhile,TRYTE Technologies integrated and purchased some companies of PCB board, highway instruments at home and abroad. Our company has become the "one stop" instrument procurement service provider worthy of the name.
      TRYTE technologies (TRYTE) mainly sell products by selling direct to customer, but also through distributors, resellers and manufacturer representatives, telephone sales and e-commerce sales, customers cover all over 80% of the world's countries and regions.TRYTE have solutions with rules adaptability according to the specific requirements of the design, from the instrument to some laboratories or departments.Whichever kind of solution you choose, you can fully trust it, because it is proved from 100, 00 successful results, leading development process, and decades of actual certification experience.

Engler Viscometer-Engler Viscometer (Double Units) -Oil Testing Instrument


Why choose us?

1. We supply high quality products with reasonable price.
2. We are the professional manufacturer;
3. Advanced production machine;
4. Strict quality control system;
5. Ten people research&develop team;
6. We have professional sales team;

Engler Viscometer-Engler Viscometer (Double Units) -Oil Testing Instrument

 

 

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now
Contact Supplier