Customization: | Available |
---|---|
Appliance: | The Analysis of Environmental Samples |
Ray Type: | No |
Suppliers with verified business licenses
Audited by an independent third-party inspection agency
TR-TCIC-01 Ion Chromatograph |
Ion Chromatograph-Full Auto Ion Chromatograph Equipment
Features:
Can equipped with anion/ cat ion dual analysis system, single-column anion /cationic double-column dual work way; Can equipped with different types of separator column to analyze inorganic anions, alkali metals, alkaline-earth metals, ammonium ion, iodide ion, sulfion, cryanide ion , organic acid , amino acid and so on; sequential detection methods, fast in analysis, sensitive and excellent in reproduction.
Technical specifications and standards:
Dimension
Length (330mm)×width (415mm)× height (500mm)
working environment
- Temperature: 10~30ºC
- humidity :25~85%
- power:AC220V±10% 50HZ
Testing range
- 10 kinds of anions (F-,Br-,CI-,SO42-,NO3-,NO2-,HPO42- BrO3-,ClO3-,ClO2- ) and 8 kinds of Cations (Li+,Na+,NH4+,K+ ,Ca2+,Mg2+,Sr2+,Ba2+ )can be tested at one time.
- If ampere detector is available, anions( like iodine, sulfur, and cyanide), cations ( like lead, copper, zinc and cadmium), and organic objects can be detected. (Detection limit: I- 5ppb,S2- 5 ppb,CN- 5 ppb,Cu2+0.5 ppb,Zn2+ 1 ppb,Pb2+ 0.2 ppb,Cd2+ 0.1 ppb)
Anions analyze limit: Cl prior to 0.2ppb
Testing time: density testing of F-,Br-,CI-,SO42-,NO3-,NO2-,HPO42- BrO3-,ClO3-,ClO2- within 20 minutes
Repeatability of multi-testing is better than 2%
Configuration:
The detection of anions and cations are time-sharing. When the anions and cations are detected alternately, the chromatographic column need to be switched and more than half an hour is needed for washing the flow system. It is suitable for customers with limited budget and a small number of daily testing samples.
Order |
Unit name |
Quan-tity |
Origin |
Notes |
1 |
Column box and thermostat system |
1 |
Puren |
|
2 |
Conductivity detector |
1 |
Puren |
|
3 |
Ampere detector |
1 |
Puren |
can detect heavy metals like Cu2 +, Zn2 +, Pb2 +, Cd2 + |
4 |
High-pressure pump |
1 |
Imported from Germany |
42Mpa endurable |
5 |
Six-way injection valve |
1 |
Imported from the USA or Japan |
Stainless steel, 60Mpa endurable |
6 |
Flowing pipe |
1 |
Imported originally |
|
7 |
Anion separation column |
1 |
Original Shodex from Japan |
Can analyze F- , Br-,CI-, SO42-, NO3-, NO2-, HPO42-, BrO3-, bromate, ClO3-, ClO2- etc. at one time |
8 |
Cathodic protection column |
1 |
Domestic |
|
9 |
Anion automatically renewable Suppressor |
1 |
Puren |
automatically recycling with the eluent waste |
10 |
Cation separation column |
1 |
imported |
can detect Li+,Na+,NH4+,K+ ,Ca2+,Mg2+,Sr2+,Ba2+ etc. at one time |
11 |
chromatography workstation |
1 |
Puren |
|
12 |
Accessories |
1 set |
Puren |
|
2. Configuration of primary hardware
2.1 Conductivity Detector
Precise 5-electrod conductivity detector: main technical performance
5-electrod Conductivity pool: 316 stainless steel ring deactivated electrode, pool size ≤ 1.2ul. With electronic thermostat, temperature accuracy: 5 ~ 50 ºC ± 0.05 ºC
Resolution: not less than 1 / 20000 (≤ 0.025ns)
Baseline noise: less than 0.6% Fs
Baseline drift: less than ± 2.0% Fs
Range: 0 ~ 3500us. Select files with manual and automatic functions.
Output Voltage: 0 ~ 1000mv.
Automatic zero adjustment range:-1000mv ~ +1000 mv.
Suppressor current: 0 ~ 150mA. Increments 1mA, set by the user on the screen.
Can analyze various types of inorganic anions, organic acids, alkali metal, alkaline earth metals, ammonium and quaternary ammonium plasma
2.2 The high-pressure infusion pump
The machine is microprocessor-controlled dual-piston reciprocating pump, equipped on the fluid path with a buffer and pressure sensors which reduce the pump pulse to a minimum level. Advanced sealing technology enables the pump to work at higher pressure.
Pressure range |
0-42.0MPa(stainless iron,ceramic-lined, steel lined with titanium)0~35MPa(PEEK) |
Flow range |
0.001-9.999mL/min |
Flow accuracy |
RSD<0.1% |
Flow error |
<±0.5% |
Pressure sensor |
Pressure display accuracy: 0.1Mpa |
Over-pressure protection |
When working pressure is above or below the upper limit or lower limit set, the pump will turn itself off and set the alarm |
Material of pump and flow path |
PEEK,stainless iron,ceramic-lined, steel lined with titanium( up to the user's choice) |
Origin |
Germany, the USA, China |
2.3 Flow system
2.4 Chromatographic column
2.5 Chromatographic column and conductivity pool thermostatic system
2.6 Chromatographic Workstation
2.7Ampere detector: (optional according to customer's requirements, not included in the above quote)
Four kinds of detection methods: DC amps, pulsed amperometric, amperometric, differential pulse voltammetry. By way of flow path or flow injection and the selection of suitable working electrode, the above four methods of measurement can be achieved. Apply to detection of anions (like iodine, sulfur, cyanide), cations( like lead, copper, zinc, cadmium) and organic.
Detection range: 1μg/L-1mg/L
Detection limit: I- 5ppb,S2- 5 ppb,CN- 5 ppb,Cu2+ 0.5 ppb,Zn2+ 1 ppb,Pb2+ 0.2 ppb,Cd2+ 0.1 ppb
3. Instrument peripherals configuration (self-selection by the customer, prices are not included in the above quote)
3.1 Computer
3.1.1 role: to assist the PIC-10-type halogen dedicated tester for data processing
3.1.2 Configuration: Operating System Configuration: OS - Windows 2000/XP
3.1.3 Memory: 512M
3.1.4 Display Monitor: 17 "SVGA LCD
3.1.5 Hard disk HD: 80G or more
3.1.6 CD-ROM DVD-ROM: 24X or more
3.1.7 CPU: P4 2.6
3.2 Color Inkjet Printers
3.2.1 Role: output the results from the computer.
4. Test spectra:
Order |
Remaining time |
Name |
Density |
Peak area |
Peak Seperation |
Theoretical plate number |
1 |
6.207 |
F |
1.0000 |
532199 |
8.26 |
4492 |
2 |
9.521 |
BrO3 |
5.0000 |
343348 |
2.34 |
8232 |
3 |
10.501 |
Cl |
2.0000 |
736985 |
6.21 |
10849 |
4 |
13.323 |
NO2 |
4.0000 |
791700 |
7.66 |
11735 |
5 |
17.483 |
Br |
6.0000 |
933260 |
5.29 |
14697 |
6 |
20.848 |
NO3 |
6.0000 |
1221725 |
7.88 |
15243 |
7 |
26.863 |
HPO4 |
8.0000 |
532169 |
5.30 |
16871 |
8 |
31.571 |
SO4 |
8.0000 |
2139946 |
0.00 |
18808 |
Total 45.0000 7231332
TR-TCIC-01 Ion Chromatograph (Daul System) |
Features:
Can equipped with anion/ cat ion dual analysis system, single-column anion /cationic double-column dual work way; Can equipped with different types of separator column to analyze inorganic anions, alkali metals, alkaline-earth metals, ammonium ion, iodide ion, sulfion, cryanide ion , organic acid , amino acid and so on; sequential detection methods, fast in analysis, sensitive and excellent in reproduction.
Technical specifications and standards:
Dimension
Length (330mm)×width (415mm)× height (500mm)
working environment
- Temperature: 10~30ºC
- humidity: 25~85%
- power: AC220V±10% 50HZ
Testing range
- 10 kinds of anions (F-,Br-,CI-,SO42-,NO3-,NO2-,HPO42- BrO3-,ClO3-,ClO2- ) and 8 kinds of Cations (Li+,Na+,NH4+,K+ ,Ca2+,Mg2+,Sr2+,Ba2+ )can be tested at one time.
- If ampere detector is available, anions( like iodine, sulfur, and cyanide), cations ( like lead, copper, zinc and cadmium), and organic objects can be detected. (Detection limit: I- 5ppb,S2- 5 ppb,CN- 5 ppb,Cu2+0.5 ppb,Zn2+ 1 ppb,Pb2+ 0.2 ppb,Cd2+ 0.1 ppb)
Anions analyze limit: Cl prior to 0.2ppb
Testing time: density testing of F-,Br-,CI-,SO42-,NO3-,NO2-,HPO42- BrO3-,ClO3-,ClO2- within 20 minutes
Repeatability of multi-testing is better than 2%
Configuration:
Anions and cations can be detected simultaneously sampling. There is no need for switching of chromatographic columns or washing of flow system. This configuration is suitable for customers with sufficient funds and a large number of testing samples.
Order |
Unit name |
Quantity |
Origin |
Notes |
1 |
Conductivity detector |
2 |
Puren |
|
2 |
Ampere detector |
1 |
Puren |
Can detect Cu2 +, Zn2 +, Pb2 +, Cd2 + |
3 |
High-pressure stratospheric pump |
2 |
From Germany |
40Mpa |
4 |
Six-way injection valve |
2 |
From USA or Japan |
Stainless steel, 60Mpa endurable |
5 |
Flowing pipe |
2 |
Imported |
|
6 |
Anion separation column |
1 |
Original Shodex from Japan |
Can analyze F- , Br-,CI-, SO42-, NO3-, NO2-, HPO42-, BrO3-, bromate, ClO3-, ClO2- etc. at one time |
7 |
Anion automatically renewable Suppressor |
1 |
Puren |
automatically recycling with the eluent waste |
8 |
Cation separation column |
1 |
Imported |
can detect Li+,Na+,NH4+,K+ ,Ca2+,Mg2+,Sr2+,Ba2+ etc. at one time |
9 |
Dual system workstation |
1 |
Puren |
|
10 |
Accessories |
1 set |
Puren |
|
2. Configuration of primary hardware
2.1 Conductivity Detector
Precise 5-electrod conductivity detector: main technical performance
5-electrod Conductivity pool: 316 stainless steel ring deactivated electrode, pool size ≤ 1.2ul. With electronic thermostat, temperature accuracy: 5 ~ 50 ºC ± 0.05 ºC
Resolution: not less than 1 / 20000 (≤ 0.025ns)
Baseline noise: less than 0.6% Fs
Baseline drift: less than ± 2.0% Fs
Range: 0 ~ 3500us. Select files with manual and automatic functions.
Output Voltage: 0 ~ 1000mv.
Automatic zero adjustment range:-1000mv ~ +1000 mv.
Suppressor current: 0 ~ 150mA. Increments 1mA, set by the user on the screen.
Can analyze various types of inorganic anions, organic acids, alkali metal, alkaline earth metals, ammonium and quaternary ammonium plasma
2.2 The high-pressure infusion pump
The machine is microprocessor-controlled dual-piston reciprocating pump, equipped on the fluid path with a buffer and pressure sensors which reduce the pump pulse to a minimum level. Advanced sealing technology enables the pump to work at higher pressure.
Pressure range |
0-42.0MPa(stainless iron,ceramic-lined, steel lined with titanium)0~35MPa(PEEK) |
Flow range |
0.001-9.999mL/min |
Flow accuracy |
RSD<0.1% |
Flow error |
<±0.5% |
Pressure sensor |
Pressure display accuracy: 0.1Mpa |
Over-pressure protection |
When working pressure is above or below the upper limit or lower limit set, the pump will turn itself off and set the alarm |
Material of pump and flow path |
PEEK,stainless iron,ceramic-lined, steel lined with titanium( up to the user's choice) |
Origin |
Germany, the USA, China |
2.3 Flow system
2.4Chromatographic column
2.5 Chromatographic column and conductivity pool thermostatic system
2.6 Chromatographic Workstation
2.7Ampere detector: (optional according to customer's requirements, not included in the above quote)
Four kinds of detection methods: DC amps, pulsed amperometric, amperometric, differential pulse voltammetry. By way of flow path or flow injection and the selection of suitable working electrode, the above four methods of measurement can be achieved. Apply to detection of anions (like iodine, sulfur, cyanide), cations( like lead, copper, zinc, cadmium) and organic.
Detection range: 1μg/L-1mg/L
Detection limit: I- 5ppb,S2- 5 ppb,CN- 5 ppb,Cu2+ 0.5 ppb,Zn2+ 1 ppb,Pb2+ 0.2 ppb,Cd2+ 0.1 ppb
3. Instrument peripherals configuration (self-selection by the customer, prices are not included in the above quote)
3.1 Computer
3.1.1 role: to assist the PIC-10-type halogen dedicated tester for data processing
3.1.2 Configuration: Operating System Configuration: OS - Windows 2000/XP
3.1.3 Memory: 512M
3.1.4 Display Monitor: 17 "SVGA LCD
3.1.5 Hard disk HD: 80G or more
3.1.6 CD-ROM DVD-ROM: 24X or more
3.1.7 CPU: P4 2.6
3.2 Color Inkjet Printers
3.2.1 Role: output the results from the computer.
4. Test spectra:
Order |
Remaining time |
Name |
Density |
Peak area |
Peak Seperation |
Theoretical plate number |
1 |
6.207 |
F |
1.0000 |
532199 |
8.26 |
4492 |
2 |
9.521 |
BrO3 |
5.0000 |
343348 |
2.34 |
8232 |
3 |
10.501 |
Cl |
2.0000 |
736985 |
6.21 |
10849 |
4 |
13.323 |
NO2 |
4.0000 |
791700 |
7.66 |
11735 |
5 |
17.483 |
Br |
6.0000 |
933260 |
5.29 |
14697 |
6 |
20.848 |
NO3 |
6.0000 |
1221725 |
7.88 |
15243 |
7 |
26.863 |
HPO4 |
8.0000 |
532169 |
5.30 |
16871 |
8 |
31.571 |
SO4 |
8.0000 |
2139946 |
0.00 |
18808 |
Total 45.0000 7231332